diff --git a/FAQ.md b/FAQ.md
index 99c4381..fa150d0 100644
--- a/FAQ.md
+++ b/FAQ.md
@@ -13,4 +13,19 @@ Yes, it can. However, the mounting clips of the Active Cooler pass through the R
+#### 3. Why can't the PiSugar 3 fully charge and the green LED keeps flashing in a loop?
+
+This is due to the firmware design of PiSugar 3. The green LED is currently unable to indicate a fully charged state, so it will keep flashing in a loop as long as an external power source is connected. We will optimize this issue in future firmware updates.
+
+#### 4. Why does the PiSugar 3's blue LED remain on (unable to shut down) after I use the shutdown command to turn off the Raspberry Pi?
+
+For soft shutdown scenarios, the software needs to notify PiSugar 3 (Plus) to shut down. Therefore, you should check the following:
+
+* Use the command `i2cdetect -y 1` to check if the hardware is communicating properly with the Raspberry Pi. If the corresponding device address is not displayed, refer to issue 1 for troubleshooting.
+* Install `pisugar-power-manager`, select the model PiSugar 3, and ensure it runs properly (displays battery information).
+* Try the shutdown command again and observe whether PiSugar 3 shuts down correctly.
+
+
+
+