From 8b0038ac871009f3e5b840a4f2588f58f1d9e694 Mon Sep 17 00:00:00 2001 From: Jdaie <490844515@qq.com> Date: Thu, 20 Mar 2025 07:46:05 +0800 Subject: [PATCH] Updated FAQ (markdown) --- FAQ.md | 15 +++++++++++++++ 1 file changed, 15 insertions(+) diff --git a/FAQ.md b/FAQ.md index 99c4381..fa150d0 100644 --- a/FAQ.md +++ b/FAQ.md @@ -13,4 +13,19 @@ Yes, it can. However, the mounting clips of the Active Cooler pass through the R +#### 3. Why can't the PiSugar 3 fully charge and the green LED keeps flashing in a loop? + +This is due to the firmware design of PiSugar 3. The green LED is currently unable to indicate a fully charged state, so it will keep flashing in a loop as long as an external power source is connected. We will optimize this issue in future firmware updates. + +#### 4. Why does the PiSugar 3's blue LED remain on (unable to shut down) after I use the shutdown command to turn off the Raspberry Pi? + +For soft shutdown scenarios, the software needs to notify PiSugar 3 (Plus) to shut down. Therefore, you should check the following: + +* Use the command `i2cdetect -y 1` to check if the hardware is communicating properly with the Raspberry Pi. If the corresponding device address is not displayed, refer to issue 1 for troubleshooting. +* Install `pisugar-power-manager`, select the model PiSugar 3, and ensure it runs properly (displays battery information). +* Try the shutdown command again and observe whether PiSugar 3 shuts down correctly. + + + +