mirror of
https://github.com/markqvist/Reticulum.git
synced 2026-11-19 14:36:34 -05:00
Updated egress control test
This commit is contained in:
parent
f0875ac44e
commit
cadee01f9e
1 changed files with 39 additions and 1 deletions
|
|
@ -1,4 +1,4 @@
|
|||
# Partially generated with lc/kimi_k2.6
|
||||
# Partially generated with lc/kimi_k2.6 and lc/deepseek_v4_flash_q8_k_xl
|
||||
# Reviewed and approved by Mark Qvist
|
||||
import unittest
|
||||
|
||||
|
|
@ -203,4 +203,42 @@ class TestHWMLimiter(unittest.TestCase):
|
|||
self.assertEqual(iface.tx_dropped_bytes, len(framed(b"gated-frame")))
|
||||
self.assertEqual(len(iface.transmit_buffer), 0)
|
||||
|
||||
def test_12_ec_state_reset_on_teardown(self):
|
||||
print("")
|
||||
# When a dead peer escalates to teardown, the interface instance
|
||||
# persists, but the socket is closed. On initiator interfaces the
|
||||
# same instance is later re-registered on reconnection, so the
|
||||
# egress-control state and transmit buffer must be reset at
|
||||
# teardown.
|
||||
tb = TransmitBuffer()
|
||||
iface = FakeIF(tb)
|
||||
while len(tb) <= BackboneInterface.DP_EC_MID_WM: tb.append(framed(b"y" * 4096))
|
||||
iface._dp_ec_last_drain = 10.0
|
||||
iface._dp_ec_zero_ticks = BackboneInterface.DP_EC_STALL_TICKS
|
||||
iface.tx_stalled = True
|
||||
|
||||
escalated = BackboneInterface._dp_ec_evaluate(iface, 100.0)
|
||||
self.assertTrue(escalated)
|
||||
self.assertTrue(iface.torn_down)
|
||||
|
||||
# The persisted instance must be left in a clean post-teardown
|
||||
# state, ready for the reconnection cycle to re-register and
|
||||
# re-evaluate it.
|
||||
self.assertEqual(iface._dp_ec_prev_sent, 0)
|
||||
self.assertEqual(iface._dp_ec_zero_ticks, 0)
|
||||
self.assertGreaterEqual(iface._dp_ec_last_drain, 100.0)
|
||||
self.assertFalse(iface.tx_stalled)
|
||||
self.assertIsNot(iface.transmit_buffer, tb)
|
||||
self.assertEqual(len(iface.transmit_buffer), 0)
|
||||
|
||||
# Simulate the re-established connection: the same instance is
|
||||
# evaluated again. A stale dead-drain state would re-trigger the
|
||||
# teardown on this tick; a reset instance must not.
|
||||
iface.torn_down = False # This is a bit janky, but will do for
|
||||
# now as a simulation.
|
||||
re_escalated = BackboneInterface._dp_ec_evaluate(iface, 101.0)
|
||||
self.assertFalse(re_escalated)
|
||||
self.assertFalse(iface.torn_down)
|
||||
self.assertFalse(iface.tx_stalled)
|
||||
|
||||
if __name__ == "__main__": unittest.main(verbosity=2)
|
||||
Loading…
Add table
Add a link
Reference in a new issue