diff --git a/usb_config.md b/usb_config.md index d194a9e..7ea3c37 100644 --- a/usb_config.md +++ b/usb_config.md @@ -84,7 +84,7 @@ When the Femtofox is finished booting, it will blink its User LED (see below) in |
⚠️
**───   ───   ───**
3 long blinks, each lasting 1.5 seconds | USB drive mounted successfully but femtofox-config.txt was not found. Ignoring. | Config file missing. | Create configuration file as described above. | |
⚠️
**───   ───   ───   ───   ───**
5 long blinks, each lasting 1.5 seconds | USB drive mounted successfully and femtofox-config.txt was found but did not contain readable configuration data. Ignoring. | Configuration file improperly formatted or contains no data. | Check configuration file contents as described above. | |
⚠️
**──   ──   -   -**
2 long blinks, each lasting 1 second, then 2 short blinks, each lasting 1/4 of a second. Repeats twice | Error while trying to implement a Meshtastic setting after 3 attempts. Some settings may have been implemented successfully. |
  • The error may be transient.
  • Configuration file may contain improper data. |
  • Try again.
  • Check configuration file contents as described above.
  • Check the log.

    This pattern may flash before other patterns. The pattern will repeat once for each failed setting. | -|
    ✅
    **. . . . . . . . . .**
    10 very fast blinks, each lasting 1/8th of a second
    | USB drive mounted successfully, and femtofox-config.txt was found and contained configuration data which was sent for deployment. Any affected services will now restart. You can disconnect the USB drive. | This does not mean that the information in the config file is correct - only that it was readable.
    Note that the "success" boot code will flash if at least one setting is successfully read - even if the setting was not implemented successfully. | | +|

    ✅
    **. . . . . . . . . .**
    10 very fast blinks, each lasting 1/8th of a second
    | USB drive mounted successfully, and femtofox-config.txt was found and contained configuration data which was sent for deployment. Any affected services will now restart. You can disconnect the USB drive. | This does not mean that the information in the config file is correct - only that it was readable.
    Note that the "success" boot code will flash if at least one setting is successfully read - even if the setting was not implemented successfully. | | |

    ✅
    **─   ─   ─   ─   ─**
    5 medium blinks, each lasting 0.5 seconds | Boot complete. Appears on every successful boot and always appears last. | | | > \[!NOTE\]