From cd54fa4fba9efc700d0a51883d6bf01b65b98daf Mon Sep 17 00:00:00 2001
From: noon92 <40807970+noon92@users.noreply.github.com>
Date: Fri, 24 Jan 2025 18:11:11 +0200
Subject: [PATCH] usb_config.md updated from https://stackedit.io/
---
usb_config.md | 5 +----
1 file changed, 1 insertion(+), 4 deletions(-)
diff --git a/usb_config.md b/usb_config.md
index 7faa5f6..4f50d70 100644
--- a/usb_config.md
+++ b/usb_config.md
@@ -85,7 +85,7 @@ When the Femtofox is finished booting, it will blink its User LED (see below) in
|
⚠️
**____ ____ ____ ____ ____**
5 long blinks, each lasting 1.5 seconds | USB drive mounted successfully and femtofox-config.txt was found but did not contain readable configuration data. Ignoring. | Configuration file improperly formatted or contains no data. | Check configuration file contents as described above. |
| ⚠️
**___ ___ _ _**
2 long blinks, each lasting 1 second, then 2 short blinks, each lasting 1/4 of a second. Repeats twice | Error while trying to implement a Meshtastic setting after 3 attempts. Some settings may have been implemented successfully. | The error may be transient.Configuration file may contain improper data. | Try again.Check configuration file contents as described above.Check the log.
This pattern may flash before other patterns. The pattern will repeat once for each failed setting. |
| ✅
**. . . . . . . . . .**
10 very fast blinks, each lasting 1/8th of a second | USB drive mounted successfully, and femtofox-config.txt was found and contained configuration data which was sent for deployment. Any affected services will now restart. You can disconnect the USB drive. | This does not mean that the information in the config file is correct - only that it was readable.
Note that the "success" boot code will flash if at least one setting is successfully read - even if the setting was not implemented successfully. | |
-| ✅
**___ ___ ___ ___ ___**
5 medium blinks, each lasting 0.5 seconds | Boot complete. Appears on every successful boot and always appears last. | | |
+| ✅
**__ __ __ __ __**
5 medium blinks, each lasting 0.5 seconds | Boot complete. Appears on every successful boot and always appears last. | | |
> \[!NOTE\]
> Boot codes can appear in sequence - for example: one long (4 second) blink, followed by 5 medium (half second) blinks means the USB drive failed to mount, and that the boot sequence is complete.
@@ -181,6 +181,3 @@ When the Femtofox is finished booting, it will blink its User LED (see below) in
> \[!NOTE\]
> Boot codes can appear in sequence - for example: one long (4 second) blink, followed by 5 medium (half second) blinks means the USB drive failed to mount, and that the boot sequence is complete.
-
\ No newline at end of file