Keeps the fast sync mode as the default mode.

This commit is contained in:
Andrea Mazzoleni 2014-02-10 20:53:47 +01:00
parent a64b416741
commit 3dadfb99e9
10 changed files with 48 additions and 48 deletions

View file

@ -742,17 +742,17 @@ Configuration
The SIZE argument is specified in gibibytes. Where one gibi bytes
is 1073741824 bytes.
rawsync
Enables a single pass "sync" process avoding the initial hashing phase
and saving time.
In this mode no preliminary hashing is done, and the new data is hashed
directly during the parity computation when it's read for the first time,
prehash
Enables a double pass "sync" process with an initial hashing phase.
In the default "sync" mode no preliminary hashing is done, and the new
data is hashed directly during the parity computation when it's read
for the first time,
This happens when the system is under heavy pressure due all disks spinning
and CPU busy, and in such extreme conditions, if your machine has a latent
hardware problem, it's possible to encouter silent errors what cannot be
detected because the data is not yet hashed.
To avoid this problem, this "rawsync" mode is by default disabled,
but if you really trust your hardware, you can enable it, and save time.
To avoid this risk, you can enable the "prehash" mode and have all the
data hashed two times to ensure its integrity.
pool DIR
Defines the pooling directory where the virtual view of the disk