mirror of
https://github.com/amadvance/snapraid.git
synced 2026-11-25 09:26:27 -05:00
Fix various typos in comments
This commit is contained in:
parent
6220e4a5e2
commit
5249f9cb04
20 changed files with 98 additions and 98 deletions
|
|
@ -232,7 +232,7 @@ static void scan_file_allocate(struct snapraid_scan* scan, struct snapraid_file*
|
|||
/* - Sync aborted after, updating the parity to the new state, */
|
||||
/* but without saving the content file representing this new state. */
|
||||
/* - Another file is added again (exactly here) */
|
||||
/* with the hash of DELETED block not represeting the real parity state */
|
||||
/* with the hash of DELETED block not representing the real parity state */
|
||||
hash_invalid_set(block->hash);
|
||||
}
|
||||
}
|
||||
|
|
@ -304,7 +304,7 @@ static void scan_file_deallocate(struct snapraid_scan* scan, struct snapraid_fil
|
|||
/* but without saving the content file representing this new state. */
|
||||
/* - File is now deleted after the aborted sync */
|
||||
/* - Sync again, deleting the blocks (exactly here) */
|
||||
/* with the hash of CHG block not represeting the real parity state */
|
||||
/* with the hash of CHG block not representing the real parity state */
|
||||
hash_invalid_set(block->hash);
|
||||
}
|
||||
break;
|
||||
|
|
@ -606,7 +606,7 @@ static void scan_file(struct snapraid_scan* scan, int is_diff, const char* sub,
|
|||
* If the disk has persistent inodes and UUID, try a search on the past inodes,
|
||||
* to detect moved files.
|
||||
*
|
||||
* For persistent inodes we mean inodes that keep their values when the filesystem
|
||||
* For persistent inodes we mean inodes that keep their values when the file-system
|
||||
* is unmounted and remounted. This don't always happen.
|
||||
*
|
||||
* Cases found are:
|
||||
|
|
@ -620,10 +620,10 @@ static void scan_file(struct snapraid_scan* scan, int is_diff, const char* sub,
|
|||
* file recognition.
|
||||
*
|
||||
* For persistent UUID we mean that it has the same UUID as before.
|
||||
* Otherwise, if the UUID is changed, likely it's a new recreated filesystem,
|
||||
* Otherwise, if the UUID is changed, likely it's a new recreated file-system,
|
||||
* and then the inode have no meaning.
|
||||
*
|
||||
* Note that to disable the search by past inode, we do this implicitely
|
||||
* Note that to disable the search by past inode, we do this implicitly
|
||||
* removing all the past inode before searching for files.
|
||||
* This ensures that no file is found with a past inode, but at the same time,
|
||||
* it allows to find new files with the same inode, to identify them as hardlinks.
|
||||
|
|
@ -716,7 +716,7 @@ static void scan_file(struct snapraid_scan* scan, int is_diff, const char* sub,
|
|||
/* here the file matches the inode, but not the other info */
|
||||
/* if could be a modified file with the same name, */
|
||||
/* or a restored/copied file that get assigned a previously used inode, */
|
||||
/* or a filesystem with not persistent inodes */
|
||||
/* or a file-system with not persistent inodes */
|
||||
|
||||
/* for sure it cannot be already present */
|
||||
if (file_flag_has(file, FILE_IS_PRESENT)) {
|
||||
|
|
@ -728,7 +728,7 @@ static void scan_file(struct snapraid_scan* scan, int is_diff, const char* sub,
|
|||
|
||||
/* assume a previously used inode, it's the worst case */
|
||||
/* and we handle it removing the duplicate stored inode. */
|
||||
/* If the file is found by name (not necessarely in this function call), */
|
||||
/* If the file is found by name (not necessarily in this function call), */
|
||||
/* it will have the inode restored, otherwise, it will get removed */
|
||||
|
||||
/* remove from the inode set */
|
||||
|
|
@ -1435,7 +1435,7 @@ static int state_diffscan(struct snapraid_state* state, int is_diff)
|
|||
ret = fsinfo(disk->dir, &has_persistent_inode, 0, 0);
|
||||
if (ret < 0) {
|
||||
/* LCOV_EXCL_START */
|
||||
log_fatal("Error accessing disk '%s' to get filesystem info. %s.\n", disk->dir, strerror(errno));
|
||||
log_fatal("Error accessing disk '%s' to get file-system info. %s.\n", disk->dir, strerror(errno));
|
||||
exit(EXIT_FAILURE);
|
||||
/* LCOV_EXCL_STOP */
|
||||
}
|
||||
|
|
@ -1811,7 +1811,7 @@ static int state_diffscan(struct snapraid_state* state, int is_diff)
|
|||
|
||||
tommy_list_foreach(&scanlist, (tommy_foreach_func*)free);
|
||||
|
||||
/* check the filesystem on all disks */
|
||||
/* check the file-system on all disks */
|
||||
state_fscheck(state, "after scan");
|
||||
|
||||
if (is_diff) {
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue