mirror of
https://github.com/amadvance/snapraid.git
synced 2026-11-21 15:36:33 -05:00
Documentation and comment changes.
This commit is contained in:
parent
877d781204
commit
d3086339aa
10 changed files with 106 additions and 107 deletions
28
snapraid.d
28
snapraid.d
|
|
@ -101,15 +101,15 @@ Getting Started
|
|||
For example, suppose that you are interested only at one parity level
|
||||
of protection, and that your disks are present in:
|
||||
|
||||
:/mnt/diskpar <- selected disk for parity
|
||||
:/mnt/diskp <- selected disk for parity
|
||||
:/mnt/disk1 <- first disk to backup
|
||||
:/mnt/disk2 <- second disk to backup
|
||||
:/mnt/disk2 <- second disk to backup
|
||||
:/mnt/disk3 <- third disk to backup
|
||||
|
||||
you have to create the configuration file /etc/snapraid.conf with
|
||||
the following options:
|
||||
|
||||
:parity /mnt/diskpar/parity
|
||||
:parity /mnt/diskp/parity
|
||||
:content /var/snapraid/content
|
||||
:content /mnt/disk1/content
|
||||
:content /mnt/disk2/content
|
||||
|
|
@ -120,7 +120,7 @@ Getting Started
|
|||
If you are in Windows, you should use drive letters and backslashes
|
||||
instead of slashes, and if you like, also file extensions.
|
||||
|
||||
:parity E:\par\parity.par
|
||||
:parity E:\parity.par
|
||||
:content C:\snapraid\content.lst
|
||||
:content F:\array\content.lst
|
||||
:content G:\array\content.lst
|
||||
|
|
@ -586,11 +586,11 @@ Configuration
|
|||
For each parity file specified, one additional level of protection
|
||||
is enabled:
|
||||
|
||||
* q-parity enables RAID6 Double Parity
|
||||
* r-parity enables RAIDTP Triple Parity
|
||||
* s-parity enables RAIDQP Quad Parity
|
||||
* t-parity enables RAIDPP Penta Parity
|
||||
* u-parity enables RAIDHP Hexa Parity
|
||||
* q-parity enables RAID6 double parity
|
||||
* r-parity enables triple parity
|
||||
* s-parity enables quad parity
|
||||
* t-parity enables penta (five) parity
|
||||
* u-parity enables hexa (six) parity
|
||||
|
||||
Each parity level requires also all the files of the previous levels.
|
||||
|
||||
|
|
@ -693,8 +693,8 @@ Configuration
|
|||
Examples
|
||||
An example of a typical configuration for Unix is:
|
||||
|
||||
:parity /mnt/diskpar/parity
|
||||
:content /mnt/diskpar/content
|
||||
:parity /mnt/diskp/parity
|
||||
:content /mnt/diskp/content
|
||||
:content /var/snapraid/content
|
||||
:disk d1 /mnt/disk1/
|
||||
:disk d2 /mnt/disk2/
|
||||
|
|
@ -704,9 +704,9 @@ Configuration
|
|||
|
||||
An example of a typical configuration for Windows is:
|
||||
|
||||
:parity E:\par\parity
|
||||
:content E:\par\content
|
||||
:content C:\snapraid\content
|
||||
:parity E:\parity.par
|
||||
:content E:\content.lst
|
||||
:content C:\snapraid\content.lst
|
||||
:disk d1 G:\array\
|
||||
:disk d2 H:\array\
|
||||
:disk d3 I:\array\
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue