# SMART Drive Monitoring
|
||
|
|
|
||
|
|
SMART (Self-Monitoring, Analysis and Reporting Technology) provides early warning of drive
|
||
|
|
failures. The Controller monitors SMART data for all connected drives.
|
||
|
|
|
||
|
|
## Drive Health Assessment
|
||
|
|
|
||
|
|
Each drive displays an overall health assessment:
|
||
|
|
|
||
|
|
| Status | Meaning |
|
||
|
|
|----------|----------------------------------------------|
|
||
|
|
| **PASS** | Drive is healthy, no issues detected |
|
||
|
|
| **WARN** | Potential issues detected, monitor closely |
|
||
|
|
| **FAIL** | Drive is failing or has failed, replace soon |
|
||
|
|
|
||
|
|
_Image taken from a WROLPi with two external USB disks_
|
||
|
|
|
||
|
|

|
||
|
|
|
||
|
|
## Monitored Attributes
|
||
|
|
|
||
|
|
### Temperature
|
||
|
|
|
||
|
|
Current drive temperature in Celsius. High temperatures can indicate:
|
||
|
|
|
||
|
|
- Poor ventilation
|
||
|
|
- Heavy workload
|
||
|
|
- Impending failure
|
||
|
|
|
||
|
|
Most drives operate safely below 50°C. Temperatures above 60°C may reduce drive lifespan.
|
||
|
|
|
||
|
|
### Power-On Hours
|
||
|
|
|
||
|
|
Total hours the drive has been powered on. This helps estimate drive age and remaining lifespan.
|
||
|
|
Most drives are rated for 3-5 years of continuous operation (26,000-44,000 hours).
|
||
|
|
|
||
|
|
### Reallocated Sector Count
|
||
|
|
|
||
|
|
Number of bad sectors that have been remapped to spare sectors. A small number is normal over
|
||
|
|
time, but rapid increases indicate drive degradation.
|
||
|
|
|
||
|
|
### Pending Sector Count
|
||
|
|
|
||
|
|
Sectors waiting to be remapped. These are sectors that had read errors but haven't been
|
||
|
|
reallocated yet. Non-zero values warrant monitoring.
|
||
|
|
|
||
|
|
## Viewing Detailed SMART Data
|
||
|
|
|
||
|
|
Click on a drive's SMART status to view the full SMART attributes table. This includes:
|
||
|
|
|
||
|
|
- All SMART attribute values
|
||
|
|
- Threshold values
|
||
|
|
- Raw values
|
||
|
|
- Worst recorded values
|
||
|
|
|
||
|
|

|
||
|
|
|
||
|
|
## Drives Without SMART
|
||
|
|
|
||
|
|
Some drives don't support SMART monitoring:
|
||
|
|
|
||
|
|
- USB flash drives
|
||
|
|
- SD cards
|
||
|
|
- Some external enclosures that don't pass SMART data
|
||
|
|
- Virtual disks
|
||
|
|
|
||
|
|
These drives will show "SMART not available" in the status.
|
||
|
|
|
||
|
|
## Recommendations
|
||
|
|
|
||
|
|
- **Check SMART status regularly** - Weekly checks can catch problems early
|
||
|
|
- **Replace WARN drives soon** - Don't wait for failure
|
||
|
|
- **Backup immediately on FAIL** - Data loss may be imminent
|
||
|
|
- **Monitor temperature** - Ensure adequate cooling
|
||
|
|
|
||
|
|
## Docker Mode
|
||
|
|
|
||
|
|
SMART monitoring requires direct hardware access and is not available in Docker deployments.
|
||
|
|
Monitor drive health from the host system instead.
|
||
|
|
|
||
|
|

|