mirror of
https://github.com/lrnselfreliance/wrolpi.git
synced 2026-10-26 19:01:39 -04:00
Calculators: add 4-Wire Kelvin segment to the Electrical Calculator.
Shows the expected millivolt drop across a single wire at 1A, 5A, and 10A so a wire can be verified with a known current and sense leads. Shares the length, units, and wire type with the Power Loss calculator (state lifted to the parent, same localStorage keys). Length is not doubled because the sense leads measure across one conductor. Includes a wire temperature input (default room temperature, °F/°C follows the SAE toggle, stored canonically in Celsius) which corrects resistance using the material's temperature coefficient. Adds Solid/Stranded Aluminum wire types with published resistance tables for both unit systems, and aluminum's 0.403%/°C coefficient. Fixes erroneous copper resistance values: solid 6 AWG was 0.3134 instead of the published 0.3951 Ohm/kft, and stranded 0/2/4 AWG were decimal typos (0.022/0.019/0.038 instead of 0.122/0.194/0.308 - the table is solid x 1.24 throughout). New tests enforce monotonicity and ratio consistency. Co-Authored-By: Claude Fable 5 <noreply@anthropic.com>
This commit is contained in:
parent
b98ebf2a7f
commit
ee0e85a69c
2 changed files with 231 additions and 12 deletions
|
|
@ -175,14 +175,14 @@ export function OhmsLawCalculator({setVolts}) {
|
|||
}
|
||||
|
||||
// Dropdown options for wire types
|
||||
const resistancesPerKFeet = {
|
||||
export const resistancesPerKFeet = {
|
||||
solid: {
|
||||
'0000 AWG': 0.049,
|
||||
'00 AWG': 0.0779,
|
||||
'0 AWG': 0.0982,
|
||||
'2 AWG': 0.1563,
|
||||
'4 AWG': 0.2485,
|
||||
'6 AWG': 0.3134,
|
||||
'6 AWG': 0.3951,
|
||||
'8 AWG': 0.628,
|
||||
'10 AWG': 0.9987,
|
||||
'12 AWG': 1.588,
|
||||
|
|
@ -194,9 +194,9 @@ const resistancesPerKFeet = {
|
|||
stranded: {
|
||||
'0000 AWG': 0.0608,
|
||||
'00 AWG': 0.0967,
|
||||
'0 AWG': 0.022,
|
||||
'2 AWG': 0.019,
|
||||
'4 AWG': 0.038,
|
||||
'0 AWG': 0.122,
|
||||
'2 AWG': 0.194,
|
||||
'4 AWG': 0.308,
|
||||
'6 AWG': 0.491,
|
||||
'8 AWG': 0.778,
|
||||
'10 AWG': 1.24,
|
||||
|
|
@ -205,8 +205,37 @@ const resistancesPerKFeet = {
|
|||
'16 AWG': 4.99,
|
||||
'18 AWG': 7.95,
|
||||
},
|
||||
solid_aluminum: {
|
||||
'0000 AWG': 0.0804,
|
||||
'00 AWG': 0.128,
|
||||
'0 AWG': 0.161,
|
||||
'2 AWG': 0.256,
|
||||
'4 AWG': 0.408,
|
||||
'6 AWG': 0.648,
|
||||
'8 AWG': 1.03,
|
||||
'10 AWG': 1.64,
|
||||
'12 AWG': 2.61,
|
||||
'14 AWG': 4.14,
|
||||
'16 AWG': 6.59,
|
||||
'20 AWG': 16.7,
|
||||
'24 AWG': 42.1,
|
||||
},
|
||||
stranded_aluminum: {
|
||||
'0000 AWG': 0.082,
|
||||
'00 AWG': 0.130,
|
||||
'0 AWG': 0.164,
|
||||
'2 AWG': 0.261,
|
||||
'4 AWG': 0.416,
|
||||
'6 AWG': 0.661,
|
||||
'8 AWG': 1.05,
|
||||
'10 AWG': 1.67,
|
||||
'12 AWG': 2.66,
|
||||
'14 AWG': 4.22,
|
||||
'16 AWG': 6.72,
|
||||
'18 AWG': 10.7,
|
||||
},
|
||||
};
|
||||
const resistancesPerKm = {
|
||||
export const resistancesPerKm = {
|
||||
solid: {
|
||||
['120 mm²']: 0.153,
|
||||
['70 mm²']: 0.272,
|
||||
|
|
@ -236,6 +265,36 @@ const resistancesPerKm = {
|
|||
['1 mm²']: 18.1,
|
||||
['0.75 mm²']: 24.5,
|
||||
['0.5 mm²']: 36.0
|
||||
},
|
||||
solid_aluminum: {
|
||||
['120 mm²']: 0.235,
|
||||
['70 mm²']: 0.403,
|
||||
['50 mm²']: 0.564,
|
||||
['25 mm²']: 1.13,
|
||||
['16 mm²']: 1.76,
|
||||
['10 mm²']: 2.82,
|
||||
['6 mm²']: 4.70,
|
||||
['4 mm²']: 7.05,
|
||||
['2.5 mm²']: 11.3,
|
||||
['1.5 mm²']: 18.8,
|
||||
['1 mm²']: 28.2,
|
||||
['0.75 mm²']: 37.6,
|
||||
['0.5 mm²']: 56.4
|
||||
},
|
||||
stranded_aluminum: {
|
||||
['120 mm²']: 0.240,
|
||||
['70 mm²']: 0.411,
|
||||
['50 mm²']: 0.575,
|
||||
['25 mm²']: 1.15,
|
||||
['16 mm²']: 1.80,
|
||||
['10 mm²']: 2.88,
|
||||
['6 mm²']: 4.79,
|
||||
['4 mm²']: 7.19,
|
||||
['2.5 mm²']: 11.5,
|
||||
['1.5 mm²']: 19.2,
|
||||
['1 mm²']: 28.8,
|
||||
['0.75 mm²']: 38.4,
|
||||
['0.5 mm²']: 57.5
|
||||
}
|
||||
};
|
||||
|
||||
|
|
@ -244,6 +303,8 @@ const resistancesPerKm = {
|
|||
const wireTypeOptions = [
|
||||
{key: 'solid', text: 'Solid Copper', value: 'solid'},
|
||||
{key: 'stranded', text: 'Stranded Copper', value: 'stranded'},
|
||||
{key: 'solid_aluminum', text: 'Solid Aluminum', value: 'solid_aluminum'},
|
||||
{key: 'stranded_aluminum', text: 'Stranded Aluminum', value: 'stranded_aluminum'},
|
||||
];
|
||||
|
||||
// Helper function to calculate power loss
|
||||
|
|
@ -261,10 +322,7 @@ export const calcPowerLossPercent = (isSAE, volts, amps, resistancePerKiloLength
|
|||
return (voltageDrop / volts) * 100; // Return as a percentage
|
||||
};
|
||||
|
||||
const PowerLossCalculator = ({volts, setVolts}) => {
|
||||
const [wireType, setWireType] = useLocalStorage('calculators.power_loss.wire_type', 'solid');
|
||||
const [isSAE, setIsSAE] = useLocalStorage('calculators.power_loss.is_sae', true);
|
||||
const [length, setLength] = useLocalStorageInt('calculators.power_loss.length', 100);
|
||||
const PowerLossCalculator = ({volts, setVolts, wireType, setWireType, isSAE, setIsSAE, length, setLength}) => {
|
||||
const [ampsRange] = useState([1, 5, 10, 20, 40, 100]);
|
||||
|
||||
const {inverted} = React.useContext(ThemeContext);
|
||||
|
|
@ -375,10 +433,104 @@ const PowerLossCalculator = ({volts, setVolts}) => {
|
|||
</Form>
|
||||
};
|
||||
|
||||
// Resistance changes with temperature; the resistance tables are referenced at 20°C.
|
||||
export const COPPER_TEMP_COEFFICIENT = 0.00393; // per °C
|
||||
export const ALUMINUM_TEMP_COEFFICIENT = 0.00403; // per °C
|
||||
const REFERENCE_TEMPERATURE_C = 20;
|
||||
|
||||
const tempCoefficientForWireType = (wireType) =>
|
||||
wireType.includes('aluminum') ? ALUMINUM_TEMP_COEFFICIENT : COPPER_TEMP_COEFFICIENT;
|
||||
|
||||
// Helper function to calculate the expected millivolt drop across a single wire (4-wire Kelvin measurement).
|
||||
export const calcKelvinMilliVoltDrop = (amps, resistancePerKiloLength, length,
|
||||
temperatureC = REFERENCE_TEMPERATURE_C,
|
||||
tempCoefficient = COPPER_TEMP_COEFFICIENT) => {
|
||||
const temperatureFactor = 1 + tempCoefficient * (temperatureC - REFERENCE_TEMPERATURE_C);
|
||||
const resistancePerLength = (resistancePerKiloLength * temperatureFactor) / 1000;
|
||||
// Sense leads measure across the single conductor, so the length is NOT doubled.
|
||||
const resistance = length * resistancePerLength;
|
||||
return amps * resistance * 1000; // Volts to millivolts.
|
||||
};
|
||||
|
||||
const FourWireKelvinCalculator = ({wireType, isSAE, length}) => {
|
||||
const [ampsRange] = useState([1, 5, 10]);
|
||||
// Stored in Celsius; displayed in Fahrenheit when SAE. Default is room temperature.
|
||||
const [temperatureC, setTemperatureC] = useLocalStorage(
|
||||
'calculators.kelvin.temperature_c', REFERENCE_TEMPERATURE_C, parseFloat, (num) => num.toString());
|
||||
|
||||
const resistances = isSAE ? resistancesPerKFeet[wireType]
|
||||
: resistancesPerKm[wireType];
|
||||
|
||||
const displayTemperature = isSAE ? roundDigits(temperatureC * 9 / 5 + 32, 1) : roundDigits(temperatureC, 1);
|
||||
const handleTemperatureChange = (value) => {
|
||||
const temperature = parseFloat(value);
|
||||
setTemperatureC(isSAE ? (temperature - 32) * 5 / 9 : temperature);
|
||||
};
|
||||
|
||||
return <Form>
|
||||
<Header as='h1'>4-Wire Kelvin</Header>
|
||||
<p>
|
||||
Expected millivolt drop across {length} {isSAE ? 'feet' : 'meters'} of wire when driving a known
|
||||
current through it. Measure with separate sense leads at each end of the wire.
|
||||
<InfoPopup
|
||||
content='Uses the length and wire type from the Power Loss calculator above. The length is NOT doubled because the sense leads measure across a single conductor.'/>
|
||||
</p>
|
||||
|
||||
<Grid columns={2}>
|
||||
<Grid.Row>
|
||||
<Grid.Column mobile={12} tablet={12}>
|
||||
<Input fluid
|
||||
label={isSAE ? '°F' : '°C'}
|
||||
labelPosition='right'
|
||||
type='number'
|
||||
value={displayTemperature}
|
||||
onChange={(e, {value}) => handleTemperatureChange(value)}
|
||||
autoComplete="off"
|
||||
/>
|
||||
</Grid.Column>
|
||||
<Grid.Column mobile={4} tablet={2}>
|
||||
<InfoPopup
|
||||
content='Wire temperature. Resistances are referenced at 20°C (68°F) and corrected using the temperature coefficient of the wire material (copper 0.393% per °C, aluminum 0.403% per °C).'/>
|
||||
</Grid.Column>
|
||||
</Grid.Row>
|
||||
</Grid>
|
||||
|
||||
<Table unstackable compact celled definition>
|
||||
<TableHeader>
|
||||
<TableRow>
|
||||
<TableHeaderCell/>
|
||||
{ampsRange.map(amp => <TableHeaderCell key={amp}>{amp}A</TableHeaderCell>)}
|
||||
</TableRow>
|
||||
</TableHeader>
|
||||
<TableBody>
|
||||
{Object.entries(resistances).map(([size, resistance]) => (
|
||||
<TableRow key={size}>
|
||||
<TableCell>{size}</TableCell>
|
||||
{ampsRange.map(amp => {
|
||||
const milliVolts = calcKelvinMilliVoltDrop(
|
||||
amp, resistance, length, temperatureC, tempCoefficientForWireType(wireType));
|
||||
return <TableCell key={`${size}-${amp}`}>
|
||||
{roundDigits(milliVolts, 1)} mV
|
||||
</TableCell>
|
||||
})}
|
||||
</TableRow>
|
||||
))}
|
||||
</TableBody>
|
||||
</Table>
|
||||
</Form>
|
||||
};
|
||||
|
||||
export const ElectricalCalculators = () => {
|
||||
const [volts, setVolts] = useLocalStorageInt('calculators.electrical.volts', 120);
|
||||
const [wireType, setWireType] = useLocalStorage('calculators.power_loss.wire_type', 'solid');
|
||||
const [isSAE, setIsSAE] = useLocalStorage('calculators.power_loss.is_sae', true);
|
||||
const [length, setLength] = useLocalStorageInt('calculators.power_loss.length', 100);
|
||||
return <Container>
|
||||
<Segment><OhmsLawCalculator setVolts={setVolts}/></Segment>
|
||||
<Segment><PowerLossCalculator volts={volts} setVolts={setVolts}/></Segment>
|
||||
<Segment><PowerLossCalculator volts={volts} setVolts={setVolts}
|
||||
wireType={wireType} setWireType={setWireType}
|
||||
isSAE={isSAE} setIsSAE={setIsSAE}
|
||||
length={length} setLength={setLength}/></Segment>
|
||||
<Segment><FourWireKelvinCalculator wireType={wireType} isSAE={isSAE} length={length}/></Segment>
|
||||
</Container>
|
||||
}
|
||||
|
|
|
|||
|
|
@ -1,4 +1,10 @@
|
|||
import {calcPowerLossPercent} from "./ElectricalCalculators";
|
||||
import {
|
||||
ALUMINUM_TEMP_COEFFICIENT,
|
||||
calcKelvinMilliVoltDrop,
|
||||
calcPowerLossPercent,
|
||||
resistancesPerKFeet,
|
||||
resistancesPerKm,
|
||||
} from "./ElectricalCalculators";
|
||||
|
||||
describe('calcPowerLossPercent Function Tests', () => {
|
||||
test('should correctly calculate power loss percentage', () => {
|
||||
|
|
@ -7,3 +13,64 @@ describe('calcPowerLossPercent Function Tests', () => {
|
|||
expect(percent).toBeCloseTo(7.16, 2); // Use expected correct value and precision
|
||||
});
|
||||
});
|
||||
|
||||
describe('calcKelvinMilliVoltDrop Function Tests', () => {
|
||||
test('should correctly calculate millivolt drop', () => {
|
||||
// Parameters: amps, resistancePerKiloLength, length
|
||||
// 100 feet of 10 AWG solid copper (0.9987 Ω/kft) at 1A: 0.09987 Ω * 1A = 99.87 mV
|
||||
expect(calcKelvinMilliVoltDrop(1, 0.9987, 100)).toBeCloseTo(99.87, 2);
|
||||
// Same wire at 10A: 998.7 mV
|
||||
expect(calcKelvinMilliVoltDrop(10, 0.9987, 100)).toBeCloseTo(998.7, 1);
|
||||
// Length is not doubled: 50 feet at 5A is a quarter of 100 feet at 10A.
|
||||
expect(calcKelvinMilliVoltDrop(5, 0.9987, 50)).toBeCloseTo(calcKelvinMilliVoltDrop(10, 0.9987, 100) / 4, 5);
|
||||
});
|
||||
|
||||
test('should return zero for zero length or amps', () => {
|
||||
expect(calcKelvinMilliVoltDrop(0, 0.9987, 100)).toBe(0);
|
||||
expect(calcKelvinMilliVoltDrop(1, 0.9987, 0)).toBe(0);
|
||||
});
|
||||
|
||||
test('should correct resistance for temperature', () => {
|
||||
// At the 20°C reference temperature, no correction is applied.
|
||||
expect(calcKelvinMilliVoltDrop(1, 0.9987, 100, 20)).toBeCloseTo(99.87, 2);
|
||||
// Warmer wire has more resistance: 30°C is a 3.93% increase.
|
||||
expect(calcKelvinMilliVoltDrop(1, 0.9987, 100, 30)).toBeCloseTo(99.87 * 1.0393, 2);
|
||||
// Colder wire has less resistance: 0°C is a 7.86% decrease.
|
||||
expect(calcKelvinMilliVoltDrop(1, 0.9987, 100, 0)).toBeCloseTo(99.87 * 0.9214, 2);
|
||||
});
|
||||
|
||||
test('should use the given temperature coefficient', () => {
|
||||
// 100 feet of 10 AWG solid aluminum (1.64 Ω/kft) at 1A and 30°C: 164 mV plus aluminum's 4.03% increase.
|
||||
expect(calcKelvinMilliVoltDrop(1, 1.64, 100, 30, ALUMINUM_TEMP_COEFFICIENT))
|
||||
.toBeCloseTo(164 * 1.0403, 2);
|
||||
});
|
||||
});
|
||||
|
||||
describe('Resistance Table Sanity Tests', () => {
|
||||
// The tables list wire sizes from largest to smallest, so resistance must strictly increase.
|
||||
test.each([
|
||||
...Object.entries(resistancesPerKFeet),
|
||||
...Object.entries(resistancesPerKm),
|
||||
])('%s resistances increase as the wire gets smaller', (wireType, resistances) => {
|
||||
const values = Object.values(resistances);
|
||||
for (let i = 1; i < values.length; i++) {
|
||||
expect(values[i]).toBeGreaterThan(values[i - 1]);
|
||||
}
|
||||
});
|
||||
|
||||
test('solid copper matches published values', () => {
|
||||
// Published solid copper resistance at 20°C is 0.3951 Ω/kft for 6 AWG.
|
||||
expect(resistancesPerKFeet.solid['6 AWG']).toBeCloseTo(0.3951, 2);
|
||||
});
|
||||
|
||||
test('stranded copper is a consistent ratio of solid copper', () => {
|
||||
// The stranded copper table was built as solid × 1.24; every entry must match that ratio.
|
||||
for (const [size, resistance] of Object.entries(resistancesPerKFeet.stranded)) {
|
||||
const solid = resistancesPerKFeet.solid[size];
|
||||
if (solid === undefined) {
|
||||
continue; // Stranded has 18 AWG which solid does not.
|
||||
}
|
||||
expect(resistance / solid).toBeCloseTo(1.24, 1);
|
||||
}
|
||||
});
|
||||
});
|
||||
|
|
|
|||
Loading…
Add table
Add a link