The attribution at the bottom of the page is enough. The line under the
location now only appears to report the data's state: loading, failed to
load, or replaced by the user's own values. Bumps wrolpi-help for the
refreshed screenshot.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The full NASA POWER acknowledgment, license and changes now sit in a small
"Data attribution" section at the end of the calculator, always visible,
instead of behind a link under the location. The source line under the
location points to it. Bumps wrolpi-help to match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- PWM usable power now uses the string's voltage (Vmp x panels in series),
delivers nothing when the charging voltage is at or above the string's Voc,
and falls off between Vmp and Voc. The "too little voltage" warning covers
PWM as well as MPPT. Previously two panels in series counted double, and a
panel that could not charge a 48 V bank counted as fully usable.
- A Voc temperature coefficient entered without its minus sign is treated as
negative, in the math, the URL and the input, so the cold-morning check
cannot be made too generous.
- Switching Fahrenheit on or off converts the entered temperatures instead
of reinterpreting them.
- While the sunlight data downloads, the off-grid tab shows a loader rather
than asking for a location, and holds the cold-morning verdict until the
site's temperatures are known or one has been entered.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
- The calculator gains a "Data attribution" link under the location with
NASA POWER's requested acknowledgment, the data reference (Climatology API
v2.10.0, downloaded 2026/10/04), the CC BY 4.0 license, and how WROLPi
modified the data (rounded to one byte per value, temperature averaged
into 1 degree cells, interpolated between cells), which CC BY 4.0 requires.
- The build script writes the same text to solar-climatology.LICENSE.txt
beside the data, with the API version taken from NASA's responses and the
date the tiles were downloaded. A test keeps the page and file in step.
- Bumps wrolpi-help for the updated attribution in the help page.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A new "Off-grid sizing" tab sizes a battery system for the darkest month
from a list of devices (watts x hours per day):
- Battery bank for a number of days without sun, for LiFePO4 or lead-acid,
at 12, 24 or 48 V. Outdoor lead-acid is enlarged for the cold; outdoor
lithium warns against charging below 0 C.
- Panels needed, from the worst month's DC production per kW at the chosen
angle, with a button to apply the count. A PWM controller's loss (battery
voltage over the panel's Vmp) raises the count.
- Charge controller current, and the string voltage on the coldest morning
against the controller's limit, since cold panels exceed their rated Voc.
The coldest morning defaults to 25 C below the coldest monthly average.
All inputs live in the URL like the rest of the calculator.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The map's right-click (or long-press) menu gains "Calculate Solar
Performance", and each saved pin a sun button; both open the calculator at
that location. A button beside Latitude fills in the browser's current
location. Locations are rounded to 4 decimals, and longitudes from a map
panned around the world are wrapped back to -180..180.
The map removed lat/lon/z from the URL when it closed, even after navigating
to another page, which stripped the calculator's location from its URL (and
from links shared with the Share button). It now only cleans up while the
URL is still a map page.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Estimates a solar array's typical-year production from a location and the
panels; everything else has defaults under an optional "Fine-tune" section.
The model works from 12 monthly averages: Klein's average day per month, the
Erbs monthly diffuse fraction, Collares-Pereira & Rabl / Liu & Jordan hourly
split, HDKR transposition for fixed, single-axis and dual-axis arrays, then
PVWatts' ASHRAE incidence loss, SAPM cell temperature, DC power, system
losses and optional inverter. "Best for the year" and "Best for winter" sweep
the tilt.
Sunlight, diffuse, albedo and temperature come from NASA POWER's 2001-2020
climatology on a 1 degree grid, packed into app/public/data (3.1 MB, ~1 MB
gzipped) by scripts/build_solar_climatology.py and fetched only when the
calculator opens. Users can replace it with their own monthly values.
Every setting lives in the URL, with defaults left out, so the Share button
shares the whole configuration.
Against PVWatts v8 for a 1 kW fixed array: Phoenix +0.6%, Seattle +8.8%,
Anchorage +8.0% annually; these are recorded as tests.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>