@ -68,7 +68,7 @@ When the Femtofox is finished booting, it will blink its User LED (see below) in
|
|||
| LED blink pattern | Meaning | Possible causes | Solutions |
|
||||
|--|--|--|--|
|
||||
|<center>⚠️<br>________________<br>1 very long blink, lasting 5 seconds| Failed to mount USB drive. Ignoring.| <li>Invalid filesystem<li>Corrupted partition table<li>Defective USB drive<li>Defective USB OTG adapter | <li>Use a supported partition (FAT32, exFAT, NTFS, ext4)<li>Repair partition table<li>Try another USB drive<li>Try another USB OTG adapter |
|
||||
|<center>⚠️<br>\_\_\_\_\_ \_\_\_\_\_<br>2 long blinks, each lasting 1.5 seconds | USB drive mounted successfully but femtofox-config.txt contains the `dont_run_config_if_log_exists` line and a log is present on the USB drive. Ignoring.| Misconfiguration. | Remove log from USB drive or remove `dont_run_config_if_log_exists` line from femtofox-config.txt |
|
||||
|<center>⚠️<br>\_\_\_\_\_ \_\_\_\_\_<br>2 long blinks, each lasting 1.5 seconds | USB drive mounted successfully but femtofox-config.txt contains `dont_run_if_log_exists="true"` and a log is present on the USB drive. Ignoring.| Misconfiguration. | Remove log from USB drive or remove `dont_run_if_log_exists` line from femtofox-config.txt |
|
||||
|<center>⚠️<br>\_\_\_\_\_ \_\_\_\_\_ \_\_\_\_\_<br>3 long blinks, each lasting 1.5 seconds | USB drive mounted successfully but femtofox-config.txt was not found. Ignoring.| Config file missing. | Create configuration file as described above. |
|
||||
|<center>⚠️<br>\_\_\_\_\_ \_\_\_\_\_ \_\_\_\_\_ \_\_\_\_\_ \_\_\_\_\_<br>5 long blinks, each lasting 1.5 seconds | USB drive mounted successfully and femtofox-config.txt was found but did not contain readable configuration data. Ignoring.| Configuration file improperly formatted or contains no data. | Check configuration file contents as described above. |
|
||||
|<center>⚠️<br>\_\_\_ \_\_\_ \_ \_ \_\_\_ \_\_\_ \_ \_<br>2 long blinks, each lasting 1 second, then 2 short blinks, each lasting 1/4 of a second. Repeats twice | Error while trying to implement a Meshtastic setting after 3 attempts. Some settings may have been implemented successfully.| <li>The error may be transient.<li>Configuration file may contain improper data. | <li>Try again.<li>Check configuration file contents as described above.<li>Check the log.<br><br>This pattern may flash before other patterns. The pattern will repeat once for each failed setting.|
|
||||
|
|
@ -78,6 +78,6 @@ When the Femtofox is finished booting, it will blink its User LED (see below) in
|
|||
> [!NOTE]
|
||||
> Boot codes can appear in sequence - for example: one long (4 second) blink, followed by 5 medium (half second) blinks means the USB drive failed to mount, and that the boot sequence is complete.
|
||||