# Solar
|
||
|
||
The Solar calculator estimates what solar panels will produce over a typical year at any place on Earth, and
|
||
sizes a battery system to run your devices through the darkest month. It works completely offline: the sunlight
|
||
and temperature data for the whole world ship with WROLPi.
|
||
|
||
> To open it, click **Calculators** (under **More** on smaller screens), then **Solar**. Enter a location and
|
||
> your panels; everything else has sensible defaults.
|
||
|
||
Every setting is saved in the page address, so you can bookmark a design, or share it with the Share button
|
||
(the QR code carries the whole configuration).
|
||
|
||

|
||
|
||
## Example: powering an off-grid cabin
|
||
|
||
You are planning a small cabin with a refrigerator, lights, a laptop and a radio, and want to know how many
|
||
panels and how much battery to buy.
|
||
|
||
1. **Location.** Type the cabin's latitude and longitude, or click the location button to the left of Latitude
|
||
to use your device's current location. You can also right-click (or long-press) the spot on the
|
||
[Map](../map/index.md) and choose **Calculate Solar Performance**, or use the sun button beside a saved pin.
|
||
2. **Your panels.** Enter the watts printed on the panel you plan to buy (for example 400 W) and leave
|
||
**Panels** at 1 for now.
|
||
3. Click the **Off-grid sizing** tab.
|
||
4. **Your devices.** Add each device with its watts and hours of use per day. The watts are on the device's
|
||
label or power supply. A refrigerator turns on and off, so use about a third of its rating for 24 hours.
|
||
|
||

|
||
|
||
5. **Batteries.** Choose the battery type, the system voltage, and how many **days without sun** the batteries
|
||
must cover (two or three is typical). Turn on **Batteries are outdoors or unheated** if they will sit in a
|
||
cold shed.
|
||
6. Read **What you need**: the number of panels, the battery size in amp-hours and kWh, and how much of your use
|
||
your current panels would cover in the darkest month. Click **Use N panels** to apply the suggested count.
|
||
|
||

|
||
|
||
7. **Charge controller and wiring.** Copy the four numbers from the label on the back of your panel, choose your
|
||
controller, and set how many panels are wired in series. Fix anything shown in red or orange (see
|
||
[Warnings](#warnings)).
|
||
|
||
Back on the **Estimate** tab you can see the month-by-month production of the system you just sized.
|
||
|
||
## Other things it can answer
|
||
|
||
### How much do my existing panels make, and how far could I expand?
|
||
|
||
Enter your existing panels, their tilt and direction (under **Fine-tune** → **Panel angle**), and compare the
|
||
monthly table with your charge controller's or inverter's own history. Then raise **Panels** to see what an
|
||
expansion would add. If your system makes much less than the estimate, see
|
||
[Why is my system making less?](#why-is-my-system-making-less)
|
||
|
||
### Emergency and portable power
|
||
|
||
A folding panel and a portable power station can keep a radio, phones, a CPAP machine or a freezer running
|
||
through an outage. Enter the panel's watts and your few essential devices on the **Off-grid sizing** tab; the
|
||
battery size tells you what capacity of power station to look for.
|
||
|
||
### Where and how should I mount the panels?
|
||
|
||
Under **Fine-tune** → **Panel angle**, try different tilts and directions and watch the yearly total. **Best for
|
||
the year** and **Best for winter** find the best tilt for you. Under **Panel details**, compare **Tracking**
|
||
options to see whether a tracker is worth its cost. To compare two sites, such as your home and a cabin, open
|
||
each from the map.
|
||
|
||
### Will this kit work?
|
||
|
||
Kits often pair panels with a battery and controller that do not suit each other. Enter the kit on the
|
||
**Off-grid sizing** tab: a PWM controller with a high-voltage panel, a battery too small for your devices, or
|
||
too many panels in series for the controller will all show up.
|
||
|
||
### RVs, vans and boats
|
||
|
||
Panels on a vehicle roof lie flat. Set the tilt to 0 under **Fine-tune** → **Panel angle**; the direction then
|
||
makes no difference. Enter where you will spend the darkest month.
|
||
|
||
### Panels facing more than one direction
|
||
|
||
The calculator models one group of panels at a time. If you have panels on an east roof and a west roof, size
|
||
each group separately and add the results.
|
||
|
||
### Covering a utility bill
|
||
|
||
Find your yearly use in kWh on your bills, then divide it by the **kWh per year per kW of panels** on the
|
||
**Estimate** tab. The result is the kW of panels you need; divide by your panel's watts (in kW) for the number of
|
||
panels.
|
||
|
||
### Why is my system making less?
|
||
|
||
If your real output is well below the estimate in sunny months, check for:
|
||
|
||
* **Shade** from trees, buildings or chimneys, even on part of one panel. Raise **Shading** under **System
|
||
losses** to match.
|
||
* **Dirt, dust, pollen or snow** on the panels. Raise **Soiling** or **Snow**.
|
||
* **A different angle** than you entered.
|
||
* **A PWM controller** with panels rated well above the battery's voltage (see [Warnings](#warnings)).
|
||
* **A failing panel, connection or controller.**
|
||
|
||
## Reading the estimate
|
||
|
||
| Figure | Meaning |
|
||
|---|---|
|
||
| kWh per year | Expected yearly production. DC unless the inverter is turned on. |
|
||
| kWh per day, average | The yearly total divided by 365. |
|
||
| kWh per day in the worst month | What the darkest month makes each day; size off-grid systems for this. |
|
||
| kWh per year per kW of panels | Production per kilowatt of panels, for comparing sites and designs. |
|
||
| Sun hours on panel | Sunlight reaching the tilted panel, in kWh/m² per day: the honest "peak sun hours". |
|
||
|
||
## Fine-tune settings
|
||
|
||
The defaults suit a typical ground-mounted array of ordinary panels facing the equator.
|
||
|
||
| Setting | Default | Notes |
|
||
|---|---|---|
|
||
| Tilt | Your latitude | Degrees from flat. **Best for the year** and **Best for winter** set it for you. |
|
||
| Facing | Toward the equator | Compass degrees: 180 is south, 0 is north. |
|
||
| Panel type | Standard | Sets the temperature coefficient; copy yours from the datasheet for accuracy. |
|
||
| Mounting | Open rack | Panels flush against a roof run hotter and make a little less. |
|
||
| Tracking | Fixed | Single-axis turns east to west through the day; dual-axis follows the sun fully. |
|
||
| Ground reflectance | From the data | Snow reflects extra light onto tilted panels; the data includes seasonal snow. |
|
||
| System losses | 14.08% | The PVWatts defaults: soiling, shading, wiring, mismatch and more. |
|
||
| Inverter | Off | Turn on for AC output from a grid-tie or hybrid inverter. Off-grid sizing ignores it. |
|
||
|
||
## Off-grid sizing settings
|
||
|
||
| Setting | Default | Notes |
|
||
|---|---|---|
|
||
| Devices run on AC | On | Adds the inverter's loss (90% efficient by default). Turn off for 12 V devices. |
|
||
| Battery type | LiFePO4 | LiFePO4 uses 80% of its capacity; lead-acid only 50%, so it must be twice as large. |
|
||
| System voltage | 12 V | Larger systems use 24 or 48 V to keep currents and wire sizes down. |
|
||
| Days without sun | 2 | How long the batteries carry your devices through cloudy weather. |
|
||
| Panel label values | A typical 400 W panel | Voc, Vmp, Isc and the Voc temperature coefficient, from your panel's label. |
|
||
| Controller max PV voltage | 100 V | The highest panel voltage your controller accepts, from its label. |
|
||
| Coldest morning | Coldest monthly average minus 25 °C | Enter your area's record low if you know it. |
|
||
|
||
## Warnings
|
||
|
||
* **Too much voltage for the controller.** Panels make a higher voltage when cold. On a cold morning a string
|
||
of panels in series can exceed the controller's limit and destroy it. Put fewer panels in series, or buy a
|
||
controller rated for more voltage.
|
||
* **Too little voltage to charge.** An MPPT controller needs the panels' voltage well above the battery's. Put
|
||
more panels in series.
|
||
* **Uneven strings.** Every string of panels in series should have the same number of panels.
|
||
* **High current.** A lot of current needs a large controller and thick wire; a higher system voltage reduces
|
||
it.
|
||
* **PWM controllers** hold the panels at the battery's voltage, so a panel rated around 31 V delivers less than
|
||
half its power into a 12 V battery. They suit "12 V" panels (about 18 V); use MPPT for anything larger.
|
||
* **Lithium batteries** are damaged by charging below 0 °C. Keep them indoors, or buy batteries with built-in
|
||
heaters or low-temperature protection.
|
||
* **Lead-acid batteries** hold less when cold, so outdoor banks are sized larger, and a discharged battery can
|
||
freeze.
|
||
|
||
## Using your own sunlight data
|
||
|
||
The built-in data averages over areas about 69 miles (111 km) across, which can blur mountains, valleys and
|
||
coastlines. If you have better local measurements, open **Fine-tune** → **Use my own sunlight data**: the table
|
||
starts from the built-in values so you only change what you know. Sunlight is global horizontal irradiance in
|
||
kWh/m² per day, the same number as "peak sun hours" on flat ground.
|
||
|
||
## How accurate is it?
|
||
|
||
The calculator estimates a **typical** year from long-term monthly averages. Expect it to be within about
|
||
10–15% over a year, and further off in any single month; real years vary with the weather.
|
||
|
||
Compared with NREL's PVWatts for a 1 kW array, the yearly totals came within 1% in Phoenix and within 9% in
|
||
Seattle and Anchorage, where it reads somewhat high. It does not model shade from your surroundings beyond the
|
||
Shading loss.
|
||
|
||
It uses established methods: monthly averages are spread over an average day (Erbs; Collares-Pereira & Rabl;
|
||
Liu & Jordan), transposed onto the tilted panel (Hay-Davies-Klucher-Reindl), then converted to power with the
|
||
models PVWatts uses for panel temperature, angle losses, system losses and inverters.
|
||
|
||
## Data source
|
||
|
||
Sunlight, temperature and ground reflectance come from [NASA POWER](https://power.larc.nasa.gov/) 2001–2020
|
||
monthly averages, on a 1° grid. The data is licensed
|
||
[CC BY 4.0](https://creativecommons.org/licenses/by/4.0/).
|
||
|
||
The data was obtained from National Aeronautics and Space Administration (NASA) Langley Research Center's
|
||
Prediction Of Worldwide Energy Resources (POWER) project funded through the NASA Earth Science Division. The data
|
||
was obtained from the POWER Project's POWER Climatology API v2.10.0 version on 2026/10/04.
|
||
|
||
WROLPi modified the data: values are rounded to fit one byte each (0.04 kWh/m² per day for irradiance, 0.004 for
|
||
albedo, 0.5 °C for temperature), temperatures are averaged from NASA's 0.5° × 0.625° grid into 1° cells, and the
|
||
calculator interpolates between cells.
|
||
|
||
The calculator shows this attribution under **Data attribution** at the bottom of the page.
|