Updated FAQ (markdown)

Jdaie 2025-03-20 07:46:05 +08:00
parent cafd5ceaff
commit 8b0038ac87

15
FAQ.md

@ -13,4 +13,19 @@ Yes, it can. However, the mounting clips of the Active Cooler pass through the R
<img src="https://github.com/user-attachments/assets/495dbbef-a613-423d-bfc9-f7300727df36" width="500">
<img src="https://github.com/user-attachments/assets/def7246e-be5e-4d24-ab24-2ed34efa75aa" width="500">
#### 3. Why can't the PiSugar 3 fully charge and the green LED keeps flashing in a loop?
This is due to the firmware design of PiSugar 3. The green LED is currently unable to indicate a fully charged state, so it will keep flashing in a loop as long as an external power source is connected. We will optimize this issue in future firmware updates.
#### 4. Why does the PiSugar 3's blue LED remain on (unable to shut down) after I use the shutdown command to turn off the Raspberry Pi?
For soft shutdown scenarios, the software needs to notify PiSugar 3 (Plus) to shut down. Therefore, you should check the following:
* Use the command `i2cdetect -y 1` to check if the hardware is communicating properly with the Raspberry Pi. If the corresponding device address is not displayed, refer to issue 1 for troubleshooting.
* Install `pisugar-power-manager`, select the model PiSugar 3, and ensure it runs properly (displays battery information).
* Try the shutdown command again and observe whether PiSugar 3 shuts down correctly.